People who have applied fast rolling shutter doors know that the braking system has an immediate relationship with the opening and closing of fast rolling shutter doors. Its main purpose is divided into two types: working and closing. These two types of brakes are different, and the importance of fast rolling shutter door brakes in maintenance is different. The main content is as follows.
1. Used as a braking system in operation
The maintenance work time for a fast rolling shutter door cannot exceed 300 working hours, in other words, it should be carried out at most once every 300 working hours. During the inspection, it is crucial to accurately measure the thickness of the friction plate of the fast rolling shutter door brake system, and inspect and adjust the magnetic density, pins, spline shaft sleeves, teeth, and thrust rings of the brake system during operation.
2. Brake system used for shutdown
The maintenance time is not fixed and fixed, and the actual time can be determined based on the normal load application situation. Generally, maintenance is only necessary every 2-4 years. The key to maintenance is to remove damaged smoke and dust, conduct inspections at the contact points of the power switch, and immediately replace any damaged parts.
How to choose an intelligent controller for PVC fast doors?
Since the 1990s, the development trend of automation control has been very rapid overseas. Nowadays, the technology is already very complete and has made astonishing contributions. Automation control is a key part of PVC fast doors. In today's daily life, fast rolling shutter doors can save indoor space, power, energy, reduce noise, and prevent pollution and wind. Additionally, they can make the entrance look dignified and high-end, making their use very common. So how do you choose the intelligent controller for PVC fast doors?
1. Working voltage pairing: The rated current of the soft starter must match the rated current of the load.
2. Current matching: The rated voltage of the soft starter matches the rated voltage of the motor, and the current and load working capacity of the soft starter are clearly defined with a larger current.
3. Pitch pairing: This will occur when there is a constant pitch load or a speed reduction device.